How to use an air compressor is better for cutting machines

1. Precautions:

(1) Manually vent and drain the air storage tank before starting the machine every day;

(2) After starting the cold dryer for 3 minutes → starting the compressor until the pressure in the pipeline is greater than 0.5MPa → starting the adsorption dryer;

(3) When shutting down, it is necessary to ensure that the pipeline pressure is greater than 0.5MPa before shutting down the adsorption test dryer;

(4) Note that the compressor fan starts and stops normally and the temperature is normal;

(5) Please maintain the air compressor regularly in strict accordance with the air compressor maintenance regulations.

2. Impact of air compressor failure on equipment:

(1) Insufficient outlet pressure: poor cutting effect of equipment, abnormal opening of equipment cylinders, and abnormal exchange of worktables.

(2) High oil and water content in the gas outlet: contaminating the auxiliary gas path, contaminating the proportional valve, contaminating the cutting head lens, and ultimately resulting in poor cutting effectiveness.